BINARY Universal ALBS - Automatic Lift Backup System, is a three phase DSP Sine Wave Inverter Designed to generate 3 Phase -4 Wire OUT PUT to support Lift/Elevators during utility failure. In addition to this, important loads like staircase, Parking, compound & common lighting & security system can be run through this innovative product. |
|
The inverter Provides 3 Phase - 4 Wire AC Voltage to run lift & other three phase loads, utilizing the energy stored in battery bank. The inverter is customized to handle high 'in-rush' current capable of driving motor loads such as Elevators (Lift), Water Pumps, Fire pumps etc. |
? |
4 KVA 72 VDC |
? |
10 KVA 180 VDC |
? |
20 KVA 240 VDC |
? |
5 KVA 72 VDC |
? |
12 KVA 180 VDC |
? |
20 KVA 360 VDC |
? |
5 KVA 96 VDC |
? |
15 KVA 180 VDC |
? |
25 KVA 360 VDC |
? |
6 KVA 96 VDC |
? |
15 KVA 180 VDC |
? |
30 KVA 360 VDC |
? |
6 KVA 180 VDC |
? |
15 KVA 240 VDC |
? |
40 KVA 360 VDC |
? |
8 KVA 180 VDC |
? |
15 KVA 360 VDC |
? |
52-100 KVA 360 VDC |
|
|
BINARY UNIVERSAL ALBS offers a comprehensive solution for the most critical applications & incorporates an array of outstanding user friendly features keeping in mind the day-to-day needs and long term technical and commercial considerations. |
|
Salient Features |
- State of art MOSFET/IGBT based PEM technology to increase Crest Factor Tolerance & Dynamic Stability
- Auto Sense Intelligent Control Smart Charger
- High performance voltage and current regulation with DSP control
- Electronic change over, hence better reliability
- Surge load capacity up to 300%
- Quiet operation of AC motors as well as the other Inductive loads unlike that with modified Sine Wave Inverters
- Very Low Total Harmonic Distortion <3%
- Wide input voltage range
- All necessary Protection like Short Circuit, Over Temp., Battery Low/High, Mains MCB Tripped etc. with Comprehensive display
|
|
Applications |
- For providing reliable power back-up for Lift / Elevators
- As a major power supply source for water Pumps, Fire pumps & other 3 Phase critical motorized equipment
- Petrol/Diesel Dispensing (Filling) Machines
- Tread Mills & other Health Equipment in Homes/Gyms
- Major Power Back Up source in Corporate Offices as well as Call Centers
- Computers & peripherals / Office Equipment like, Scanners, Printers, Fax Machines etc.
- Emergency & Mobile Power Systems
- Air Conditioners and all compressor Based applications Like Water Cooler, Bottle Coolers, Ice Cream Parlors etc.
|
|
Technical Specification |
Description (KVA) |
4 |
5 |
6 |
8 |
10 |
12 |
15 |
20 |
25 |
30 |
40
- 70 |
70 |
|
Back-up Mode |
Out Wave Form |
Pure Sine Wave |
Nominal Battery Voltage
V DC |
72 |
72
96
180 |
96
180 |
180 |
180
360 |
180
240
360 |
180
276
360 |
276
360 |
360 |
360 |
360 |
360 |
Output Power Factor |
0.8 |
O/P Voltage (N-L) |
230V±2.5V AC |
Max. No Load
Battery. Current |
0.9A±0.2 A |
Frequency |
50Hz±1.0Hz |
Total Harmonic Distortion |
<3% |
O/P Voltage (L-L) |
400V±2.5V AC |
Full Load O/P Current/ Phase |
5.8±
0.5A |
7.3±
0.5A |
8.7±
0.5A |
12A±
0.5 |
14A±
0.5 |
17A±
0.5 |
21.5A±
0.5A |
23.5A±
0.5A |
29.5A±
0.5A |
34.9A±
0.5A |
- |
- |
Low Battery Indication |
10.5V =/- 0.2V DC Per Battery (12V DC Each) |
|
Mains Mode |
Input Voltage Range (N-L) |
140V to 280V AC± 10V AC |
Input Voltage Range (L-L) |
242V to 484V AC± 10V AC |
Max. Charging Current |
10A±1A |
Boost Charging Voltage |
14.2V =/-0.2V DC Per Battery(12V DC Each) |
Trickle Charging Voltage |
13.7V =/-0.2V DC Per Battery(12V DC Each) |
|
For Three Phase Inverter |
Change over time
(main to Battery) |
<=40milisec |
Change over time
(Battery to main) |
<=10milisec |
|
For Three Phase ALBS |
Change over Time
(main to Battery) |
<=30sec |
Change over Time
(Battery to main) |
<=10milisec |
|
Protections |
Protections |
Output Not Ok, Battery Voltage Low(4 Auto Retries), Over Load (6 Auto Retries) |
Input Voltage and Frequency, Battery Charging Voltage, All Protections |
|
Display |
Display |
Welcome Message, Capacity, Output Voltage, Output Frequency. Load Percentage |
Input Voltage and Frequency, Battery Charging, Battery Voltage, All Protections |
|
Environmental Parameters |
Operating Temperature |
0 Deg – 45 Deg. |
Acoustic Noise at 1 Meter. |
< 45 dB |
Relative Humidity |
Max 95% non- Condensing |
Thermal Management |
Integrated Cooling (Fan & Heat Sink) |
|
Weight and Dimensions |
With Packing
L x W x H in mm |
680x
500
x780 |
680x
500
x780 |
680x
500
x780 |
680x
500
x780 |
700
x500
x780 |
700x
500
x780 |
700x
500
x780 |
860x
630
x950 |
860x
630
x950 |
860
x630
x950 |
720x
990
x1450 |
- |
Without Packing
L x W x H in mm |
540x
340x
660 |
540x
340x
660 |
540x
340x
660 |
540x
340x
660 |
540x
340x
660 |
540x
340x
660 |
540x
340x
660 |
700x
340x
660 |
700x
340x
660 |
700x
340x
660 |
585x
800x
1290 |
- |
Net Wight |
72Kg |
78Kg |
88Kg |
92Kg |
92Kg |
107Kg |
107Kg |
173Kg |
217Kg |
205Kg |
- |
- |
Gross Weight |
83Kg |
89Kg |
94Kg |
105Kg |
124Kg |
117Kg |
134Kg |
220Kg |
232Kg |
245Kg |
- |
- |
|
|
|
|
|
|
|